Product Overview:
V-cone flowmeter, also known as V-cone flowmeter; V-shaped cone flowmeter; Cone flowmeter; Cone flowmeter; Internal cone flowmeter; Internal cone flowmeter, integrated V-cone flowmeter. V-cone flowmeter is a differential pressure instrument that measures fluid flow inside a pipe based on the laws of conservation of mass and energy. It utilizes the throttling effect generated by the V-cone in the flow field to measure the flow rate by monitoring the upstream and downstream pressure difference. Compared with ordinary throttling components, it has changed the throttling layout from a middle orifice throttling to a circular throttling. Practical use has proven that compared with other flow meters, V-cone flowmeters have the advantages of high long-term accuracy, good stability, limited installation conditions, wear resistance, wide measurement range, low pressure loss, and suitability for contaminated media. Moreover, the V-cone itself, as a rectifier for the flow field, has become an excellent new type of flowmeter with unique performance. The V-cone flowmeter, composed of a V-cone sensor and a differential pressure transmitter, can accurately measure the flow rate of various media within a wide Reynolds number range (8 × 103 ≤ Re ≤ 5 × 107).
Product Features:
1. Low installation requirements: front 0-3D straight pipe, rear 0-1D straight pipe section;
2. Range width ratio: usually 10:1, selecting the appropriate parameter upper limit can achieve 50:1;
3. Small pressure loss: For the same β value, the pressure loss is 1/3 to 1/5 of the orifice plate;
4. Wear resistance: After throttling the streamlined cone, a vacuum layer effect is generated on the surface of the cone, making it less prone to wear;
5. No blockage, no adhesion: The conical thorough blowing design avoids the retention of residues, condensates, or particles in the fluid;
6. Good long-term stability: The β value can remain unchanged for a long time and ensure accurate measurement over the long term;
7. High precision: 0.5 level;
8. Good repeatability: better than 0.1%;
9. Signal stability: "Signal fluctuation" is 1/10 of the orifice plate;
10. Wide range of beta values: The unique geometric shape of the V-cone flow sensor allows for a wide range of beta values;
11. Wide caliber range: DN25 to DN2000;
12. Measurable high temperature and high pressure medium: working temperature upper limit 850 ℃, upper limit pressure 40MPa;
13. Measurable dirty media (coke oven gas, blast furnace gas, raw oil, residual oil, etc.);
14. Measurable gas-liquid two-phase media (moisture, condensate, etc.);
Technical Specifications:
·Accuracy level: 0.5 level (differential pressure flow transmitter accuracy should be higher than 0.2 level, including 0.2 level), (β: 0.45-0.85, when β is 0.55 and the range ratio is 4:1, accuracy level: ≤ 0.30)
·Repeatability: 0.1%
·Work pressure: 0-40MPa (with multiple pressure levels to choose from)
·Working temperature: -40 to 850 ° C
·Environmental temperature: -40 to 65 ° C
·Installation requirements for straight pipe section: front 0-3D straight pipe, rear 0-1D straight pipe section
·Range width ratio: usually 10:1, selecting appropriate parameters can achieve 50:1
·Small pressure loss: For the same β value, the pressure loss is 1/3 to 1/5 of the orifice plate
·Caliber ranging from DN25 to DN2000